Protocol SP1 --- Page 4 of 6 |
|
|
|
| |
|
|
|
|
| |
 |
|
-
Tap Smart Tube on hard surface to ensure LyoSphere is in lower chamber and not clinging to inside of Cap
|
|
| |
|
|
|
|
| |
 |
|
-
Write down how much time has elapsed since blood was drawn from donor
-
Blood should be used within 30 minutes of blood draw, if possible
|
|
| |
|
|
|
|
| |
 |
|
-
It is important to minimize the time required to add blood to the set of three Smart Tubes
-
Remove the caps from the Smart Tubes
-
Line up the Smart Tubes in a rack
|
|
| |
|
|
|
|
| |
 |
|
-
Rock Vacutainer at least 5 times
-
Remove stopper from Vacutainer
-
Be sure to comply with your institution's regulations for safely handling blood samples
|
|
| |
|
|
|
|
| |
 |
|
-
Withdraw 1.0 milliliters of whole blood from Vacutainer
-
Place the pipette tip into the hole in the Smart Tube revealed by removing the Plug and dispense the blood into the Lower Chamber of the Smart Tube
-
IMPORTANT: ADD EXACTLY 1 MILLILITER OF BLOOD TO EACH SMART TUBE. ADDING MORE OR LESS THAN 1 MILLILITER OF BLOOD WILL CHANGE REACTION CHEMISTRY AND WILL MAKE SAMPLE UNRECOVERABLE
|
|
| |
|
|
|
|
| |
 |
|
-
Image on the left shows blood in the Lower Chamber of Smart Tube
|
|
| |
|
|
|
|
| |
 |
|
-
Screw Cap back onto Smart Tubes
|
|
| |
|
|
|
|
| |
|
|
|
|