Protocol SP1 --- Page 5 of 6

     
         
   
  • Invert Smart Tube 5 times to ensure good mixing of blood with dissolved LyoSphere

  • Work quickly, it is important to minimize the time elapsed between adding the blood to the Smart Tubes and putting the Smart Tubes in the Water Bath

 
         
   
  • Place Smart Tubes in a water bath pre-heated to 37°C

  • Incubate in water bath for EXACTLY 15 MINUTES

 
         
   
  • When the 15 minute incubation is complete immediately remove the Smart Tubes from the water bath and place in a rack at Room Temperature

  • Move to next step without delay

 
         
   
  • Break ampoule within each Smart Tube by performing the following steps:

  • Check that cap is screwed tightly onto Smart Tube

  • Hold Smart Tube between thumbs and forefingers

  • Press on body of Smart Tube with thumbs and bend Smart Tube until there is a quiet snapping sound inside of the Smart Tube

  • Repeat for each Smart Tube

  • It should only require about 10 seconds to break the ampoules for all 3 Smart Tubes

 
         
   
  • Mix blood with Proteomic Stabilizer released from Ampoule by inverting Smart Tube 7 times

  • Work quickly to minimize time between breaking the ampoules and mixing the blood with the Proteomic Stabilizer

 
         
   
  • Incubate at Room Temperature for EXACTLY 10 MINUTES

  • Use an open rack, like a wire rack

  • DO NOT USE STYROFOAM RACK

 
         
 

Previous Page

 

Next Page